Filter Results By:

Products

Applications

Manufacturers

Earth Continuity

Verifies ground is present.


Showing results: 16 - 29 of 29 items found.

  • Earth Ground Resistance Tester Kit - 3 Ranges, from 20 to 2000Ohm

    382252 - Extech Instruments Corporation

    The 382252 is an Earth Ground Resistance Tester Kit which includes all hardware necessary to measure earth ground in 3 ranges from 20 to 2000 omega. Also tests AC/DC Voltage, resistance and continuity. Featuring Automatic zero adjustment and three earth ground resistance ranges 20Ω/200Ω/2000Ω. Complete with test leads, 2 auxiliary earth bars, carrying case, protective rubber holster and six 1.5V AA batteries.

  • Earth Ground Resistance Tester Kit

    Extech 382252 - Extech Instruments Corporation

    The 382252 is an Earth Ground Resistance Tester Kit which includes all hardware necessary to measure earth ground in 3 ranges from 20 to 2000 omega. Also tests AC/DC Voltage, resistance and continuity. Featuring Automatic zero adjustment and three earth ground resistance ranges 20Ω/200Ω/2000Ω. Complete with test leads, 2 auxiliary earth bars, carrying case, protective rubber holster and six 1.5V AA batteries.

  • PAT Check Box

    369A910 - Di-Log

    The only check box to provide comprehensive verification of 17th Edition and PAT test equipment. The Powercheck tests for full earth continuity, insulation, resistance, RCD trip time, RCD trip current, touch current and flash test verification.

  • CombiVolt™ 1 Voltage/Continuity Tester

    DL6780 - Di-Log

    Testing of AC/ DC voltages from 12 to 690 V AC/DC Continuity testing with optical and acoustic indication Automatic switching between voltage and continuity Phase rotation test system Single pole phase indication Fully compliant with GS38 Fully operational voltage indication even when batteries are discharged Will not trip any RCD when testing across Live and Earth Single pole detection when L2 probe connected above 100V

  • Multi-function Tester

    MFT5010 - Summit

    It can be used to test insulation resistance, continuity, loop impedance and RCCB, earth resistance tester, five major test requirement in the electrical testing industry. Phase indicator. Can check a wide range of 3-Phase Power source from 110V to 600V

  • PAT and Installation Verification Unit

    PowerCheck 1557 - Seaward Electronic Ltd

    The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.

  • Multifunction Installation Tester

    COMBI519 - HT Italia Srl

    COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.

  • Multifunction Tester

    COMBI521 - HT Italia Srl

    COMBI521 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.

  • Multifunction Tester

    EASYTEST - HT Italia Srl

    EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.

  • TEST BOX

    6280 TB - Standard Electric Works Co., Ltd

    ● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.● Safety standard: EN 61010-1 / EN 61326-1

  • Multifunction Meter for Electrical Installations

    AMPI-530 - Amperis sl

    Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD

  • Manual PAT Testers

    Seaward Electronic Ltd

    If you are looking for a manual PAT tester with a pass fail reading or a PAT tester with readings we have a solution for you. Carry out mains supply checks, IEC lead tests, Earth continuity tests at 200mA, Insulation resistance tests to 250V and 500V, and more with these popular testers. All of our manual PAT testers are available as kits to help you streamline the way you work.

  • Electrical Safety Test Equipment

    IBEKO Power AB

    Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.

  • Multifunction Instrument

    COMBI521EV - HT Italia Srl

    COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.

Get Help